{"id":4292,"date":"2025-06-08T17:17:59","date_gmt":"2025-06-08T10:17:59","guid":{"rendered":"https:\/\/mtechnology.co.th\/en\/?p=4292"},"modified":"2025-06-16T17:26:26","modified_gmt":"2025-06-16T10:26:26","slug":"what-is-poe","status":"publish","type":"post","link":"https:\/\/mtechnology.co.th\/en\/lan-system\/what-is-poe\/","title":{"rendered":"PoE (Power over Ethernet) Testing with the Fluke LinkIQ 100"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\"><strong>What is PoE (Power over Ethernet) testing?<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">PoE (Power over Ethernet) is a technology that allows electrical power to be delivered over the same Ethernet cable as data, eliminating the need for separate power cables. This makes it easier and more convenient to install network devices such as IP cameras, IP phones, Wi-Fi access points, and other PoE-enabled devices.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">PoE testing and analysis involve evaluating the operation of Power over Ethernet systems, which safely and efficiently supply power and transmit data over a single LAN cable. The purpose of this testing is to ensure that:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>The LAN cable and PoE devices can properly transmit and receive electrical power according to standards.<br><\/li>\n\n\n\n<li>Devices powered via PoE receive appropriate voltage and current.<br><\/li>\n\n\n\n<li>The PoE system operates stably and safely, preventing damage to devices.<br><\/li>\n\n\n\n<li>There are no cable or connectivity issues that affect power delivery and data transmission.<br><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Why is PoE Testing Necessary?<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Testing the Power over Ethernet (PoE) system is an essential and critical step at every stage of installation, maintenance, and troubleshooting of network systems using PoE technology. The main reasons are as follows:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>To ensure devices receive power according to standards and safely<br><\/strong> PoE uses the same LAN cable to transmit data and deliver power to various devices such as IP cameras, access points, IP phones, and IoT devices. If the power delivery system is incorrect:<\/li>\n<\/ol>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Devices may be underpowered, leading to malfunction or frequent restarts.<br><\/li>\n\n\n\n<li>Overpowering can damage devices or cause short circuits, potentially crashing the network system.<br>PoE testing ensures the voltage and current supplied to devices are correct, safe, and compliant with standards like IEEE 802.3af, 802.3at, and 802.3bt.<br><\/li>\n<\/ul>\n\n\n\n<ol start=\"2\" class=\"wp-block-list\">\n<li><strong>To reduce system downtime and time spent on troubleshooting<br><\/strong> In networks that require continuous operation, such as security camera systems or corporate communications, PoE failures can cause temporary outages or disruptions, impacting security and operational efficiency. Testing PoE during installation and periodically helps:<\/li>\n<\/ol>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Detect problems early before damage occurs.<br><\/li>\n\n\n\n<li>Minimize time spent locating and fixing issues.<br><\/li>\n\n\n\n<li>Prevent unexpected downtime.<br><\/li>\n\n\n\n<li>Increase overall system reliability.<br><\/li>\n<\/ul>\n\n\n\n<ol start=\"3\" class=\"wp-block-list\">\n<li><strong>To prevent damage to cables and devices<br><\/strong> Non-standard or improperly installed LAN cables can overheat due to excessive current. PoE testing can:<\/li>\n<\/ol>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Verify cable continuity and correctness.<br><\/li>\n\n\n\n<li>Detect short circuits and reversed connections.<br><\/li>\n\n\n\n<li>Assess whether power sources and cables can handle the required power levels.<br><\/li>\n\n\n\n<li>Reduce risks of heat damage or electrical shorts.<br><\/li>\n<\/ul>\n\n\n\n<ol start=\"4\" class=\"wp-block-list\">\n<li><strong>To confirm compatibility of PoE devices<br><\/strong> PoE standards have multiple power classes (Class 0 to Class 8) tailored for different device types. Testing helps identify:<\/li>\n<\/ol>\n\n\n\n<ul class=\"wp-block-list\">\n<li>The power class supported and requested by end devices.<br><\/li>\n\n\n\n<li>Whether the PoE power source can allocate the correct power.<br><\/li>\n\n\n\n<li>Prevent installation of incompatible devices.<br><\/li>\n\n\n\n<li>Reduce issues caused by devices operating at incorrect power levels.<br><\/li>\n<\/ul>\n\n\n\n<ol start=\"5\" class=\"wp-block-list\">\n<li><strong>To improve network design and planning efficiency<br><\/strong> PoE testing provides clear information on:<\/li>\n<\/ol>\n\n\n\n<ul class=\"wp-block-list\">\n<li>LAN cable condition and power handling capacity.<br><\/li>\n\n\n\n<li>Performance of power sources (PoE switches, injectors).<br><\/li>\n\n\n\n<li>Power load distribution across the system.<br><\/li>\n<\/ul>\n\n\n\n<ol start=\"6\" class=\"wp-block-list\">\n<li><strong>To reduce long-term costs<br><\/strong> Though investing in PoE testing tools and time is necessary, it significantly reduces long-term expenses by:<\/li>\n<\/ol>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Lowering repair and replacement costs due to power delivery failures.<br><\/li>\n\n\n\n<li>Minimizing downtime that causes lost business opportunities.<br><\/li>\n\n\n\n<li>Preventing complex future problems.<br><\/li>\n\n\n\n<li>Enhancing overall network lifespan and cost-effectiveness.<br><\/li>\n<\/ul>\n\n\n\n<ol start=\"7\" class=\"wp-block-list\">\n<li><strong>To comply with relevant standards and regulations<\/strong><strong><br><\/strong> Many organizations and industries must follow safety and network standards such as IEEE and TIA\/EIA. PoE testing is part of certification and system validation to ensure compliance with rules and regulations.<br><\/li>\n\n\n\n<li><strong>To improve technician productivity<br><\/strong> PoE testing tools enable technicians to:<\/li>\n<\/ol>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Work faster and more accurately.<br><\/li>\n\n\n\n<li>Quickly and clearly identify root causes of problems.<br><\/li>\n\n\n\n<li>Avoid redundant work or wasted testing efforts.<br><\/li>\n\n\n\n<li>Provide comprehensive reports on PoE system status.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Real-world examples highlighting the importance of PoE testing:<\/strong><\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>An installer finds some IP cameras not powering on because the LAN cable does not support the required PoE class. PoE testing reveals insufficient voltage supply.<br><\/li>\n\n\n\n<li>An IT team notices certain access points reboot frequently; PoE testing detects cable shorts causing unstable current.<br><\/li>\n\n\n\n<li>A major logistics company reduces system downtime by programming regular weekly PoE checks, allowing them to resolve issues before they escalate.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Fluke LinkIQ 100 is a device for testing PoE.<\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/lh7-rt.googleusercontent.com\/docsz\/AD_4nXejUKv7cT0TOb_P4GdSfdvDHzLIyLO9-UjsIqGS9EXXku5dK69gKEJwSZnW6MznuwX9AZs9aXGIw0BzxYrqoJW1qZKqOXSabLcYYm3fJy3IYiSLW9Z0ZvM5RgBlbPXB7RoJean3-A?key=fKBhcm0ndkGVS79ABYTuosSr\" alt=\"\"\/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">LinkIQ\u2122 Cable+Wi-Fi+Network Tester is a testing tool used to verify cable performance up to 10 Gb\/s and assist in troubleshooting network connectivity issues. LinkIQ validates cable performance through frequency-based measurements and a wire map of the cable under test. It can also perform ping tests to check connectivity and diagnose nearby switches to identify key network problems and verify switch configurations, reducing the need for additional devices.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The LinkIQ Duo model adds Wi-Fi analysis up to Wi-Fi 6E standard (in countries where allowed), covering networks, channels, and access points, along with alerts for common configuration issues.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The IE models allow identification of miswired and split pairs on cables terminated with RJ45, M12X, M12D, and M8D connectors, supporting EtherNet\/IP, PROFINET, EtherCAT, and other Industrial Ethernet protocols.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Additional features include analog and digital toning, port blink, remote office locators, and the ability to manage test results via LinkWare\u2122 PC software.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Key Features of Fluke LinkIQ 100<\/strong><\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Trusted cable testing and the network testing you need, with Wi-Fi 6E support.<br><\/li>\n\n\n\n<li>Cable performance testing up to the 10GBASE-T standard, including troubleshooting features such as distance to fault measurement, wire mapping, and tone generation for cable tracing.<br><\/li>\n\n\n\n<li>Test and troubleshoot EtherNet\/IP, PROFINET, and EtherCAT cables with M12X, M12D, and M8D connectors for IE model versions.<br><\/li>\n\n\n\n<li>Network features include IPv4 and IPv6 ping tests and nearest switch diagnostics showing IP address, name, port\/VLAN number, and advertised data rates.<br><\/li>\n\n\n\n<li>Ethernet Alliance-certified PoE verification detects PoE classes (1-8) and power levels, and performs load testing of the power available from the connected switch.<br><\/li>\n\n\n\n<li>Wi-Fi analysis supporting Wi-Fi 6E, covering networks, channels, and access points (Duo model \u2013 6 GHz support only in countries where legally permitted).<br><\/li>\n\n\n\n<li>Manage test results and print reports via LinkWare\u2122 PC software.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>In-Depth PoE Testing<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Although Power over Ethernet (PoE) simplifies the installation of devices such as security cameras and wireless access points, a survey by the Ethernet Alliance involving over 800 respondents\u2014including installers, system integrators, and end users\u2014found that four out of five experienced difficulties integrating PoE systems. One reason is that the IEEE defines three different PoE standards, the term &#8220;PoE&#8221; is not trademarked, and there are many non-standard implementations in use.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"alignleft is-resized\"><img decoding=\"async\" src=\"https:\/\/lh7-rt.googleusercontent.com\/docsz\/AD_4nXdYnHN0LEmE4iFKqpERUECqjFxm7cIlHniYJKQO4J7-xtDEAXuVxjX1oqGoOZ5Z1mRO47uKhRZ0wXcIcccj8EoaPrtH5RQAL052LnyOihLUYnL5odJbiC1fk7JThvX1wjvJcv1Vmw?key=fKBhcm0ndkGVS79ABYTuosSr\" alt=\"\" style=\"width:254px;height:auto\"\/><\/figure>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\">To simplify PoE installation and troubleshooting, the LinkIQ tester displays the pairs supplying power, including different power levels and pairs used in dual-signature implementations. Additionally, the LinkIQ tester can simulate a load on the connection to ensure that the power advertised by the switch is actually delivered across the cabling. The LinkIQ tester is certified by the Ethernet Alliance to IEEE-802.3\u2122 standards to ensure reliable interoperability among equipment from multiple vendors.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><em>From the image:<\/em> The Power over Ethernet switch port settings show the pairs used, the available power and class, along with the PoE test results under load.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>.<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">If you&#8217;re interested in <strong>Fluke LinkIQ 100<\/strong>, or if you need to rent network testing equipment or require installation services, feel free to inquire for more information at <strong>Metro Technology Co., Ltd.<\/strong> or click here to <a href=\"https:\/\/mtechnology.co.th\/contact-us\/\">contact us.<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>What is PoE (Power over Ethernet) testing? PoE (Power o [&#8230;]\n","protected":false},"author":5,"featured_media":4293,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[96],"tags":[],"class_list":["post-4292","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-lan-system"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.7 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>PoE (Power over Ethernet) Testing with the Fluke LinkIQ 100 - MTECHNOLOGY<\/title>\n<meta name=\"description\" content=\"PoE (Power over Ethernet) is a technology that allows electrical power to be delivered over the same Ethernet cable as data\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/mtechnology.co.th\/en\/lan-system\/what-is-poe\/\" \/>\n<meta property=\"og:locale\" content=\"th_TH\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"PoE (Power over Ethernet) Testing with the Fluke LinkIQ 100 - MTECHNOLOGY\" \/>\n<meta property=\"og:description\" content=\"PoE (Power over Ethernet) is a technology that allows electrical power to be delivered over the same Ethernet cable as data\" \/>\n<meta property=\"og:url\" content=\"https:\/\/mtechnology.co.th\/en\/lan-system\/what-is-poe\/\" \/>\n<meta property=\"og:site_name\" content=\"MTECHNOLOGY\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/mtechnology.co.th\" \/>\n<meta property=\"article:published_time\" content=\"2025-06-08T10:17:59+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-06-16T10:26:26+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/mtechnology.co.th\/en\/wp-content\/uploads\/2025\/06\/Fluke-LinkIQ-100-EN.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"600\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"jjsita26\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"jjsita26\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"8 \u0e19\u0e32\u0e17\u0e35\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/mtechnology.co.th\\\/en\\\/lan-system\\\/what-is-poe\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/mtechnology.co.th\\\/en\\\/lan-system\\\/what-is-poe\\\/\"},\"author\":{\"name\":\"jjsita26\",\"@id\":\"https:\\\/\\\/mtechnology.co.th\\\/en\\\/#\\\/schema\\\/person\\\/2bd4e3f6a4d5782ba602167ce70dbd29\"},\"headline\":\"PoE (Power over Ethernet) Testing with the Fluke LinkIQ 100\",\"datePublished\":\"2025-06-08T10:17:59+00:00\",\"dateModified\":\"2025-06-16T10:26:26+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/mtechnology.co.th\\\/en\\\/lan-system\\\/what-is-poe\\\/\"},\"wordCount\":1194,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/mtechnology.co.th\\\/en\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/mtechnology.co.th\\\/en\\\/lan-system\\\/what-is-poe\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/mtechnology.co.th\\\/en\\\/wp-content\\\/uploads\\\/2025\\\/06\\\/Fluke-LinkIQ-100-EN.jpg\",\"articleSection\":[\"LAN System\"],\"inLanguage\":\"th\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/mtechnology.co.th\\\/en\\\/lan-system\\\/what-is-poe\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/mtechnology.co.th\\\/en\\\/lan-system\\\/what-is-poe\\\/\",\"url\":\"https:\\\/\\\/mtechnology.co.th\\\/en\\\/lan-system\\\/what-is-poe\\\/\",\"name\":\"PoE (Power over Ethernet) Testing with the Fluke LinkIQ 100 - MTECHNOLOGY\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/mtechnology.co.th\\\/en\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/mtechnology.co.th\\\/en\\\/lan-system\\\/what-is-poe\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/mtechnology.co.th\\\/en\\\/lan-system\\\/what-is-poe\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/mtechnology.co.th\\\/en\\\/wp-content\\\/uploads\\\/2025\\\/06\\\/Fluke-LinkIQ-100-EN.jpg\",\"datePublished\":\"2025-06-08T10:17:59+00:00\",\"dateModified\":\"2025-06-16T10:26:26+00:00\",\"description\":\"PoE (Power over Ethernet) is a technology that allows electrical power to be delivered over the same Ethernet cable as data\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/mtechnology.co.th\\\/en\\\/lan-system\\\/what-is-poe\\\/#breadcrumb\"},\"inLanguage\":\"th\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/mtechnology.co.th\\\/en\\\/lan-system\\\/what-is-poe\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"th\",\"@id\":\"https:\\\/\\\/mtechnology.co.th\\\/en\\\/lan-system\\\/what-is-poe\\\/#primaryimage\",\"url\":\"https:\\\/\\\/mtechnology.co.th\\\/en\\\/wp-content\\\/uploads\\\/2025\\\/06\\\/Fluke-LinkIQ-100-EN.jpg\",\"contentUrl\":\"https:\\\/\\\/mtechnology.co.th\\\/en\\\/wp-content\\\/uploads\\\/2025\\\/06\\\/Fluke-LinkIQ-100-EN.jpg\",\"width\":1200,\"height\":600,\"caption\":\"Fluke LinkIQ 100\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/mtechnology.co.th\\\/en\\\/lan-system\\\/what-is-poe\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/mtechnology.co.th\\\/en\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"PoE (Power over Ethernet) Testing with the Fluke LinkIQ 100\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/mtechnology.co.th\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/mtechnology.co.th\\\/en\\\/\",\"name\":\"MTECHNOLOGY\",\"description\":\"\u0e40\u0e21\u0e42\u0e17\u0e23 \u0e40\u0e17\u0e04\u0e42\u0e19\u0e42\u0e25\u0e22\u0e35\",\"publisher\":{\"@id\":\"https:\\\/\\\/mtechnology.co.th\\\/en\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/mtechnology.co.th\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"th\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/mtechnology.co.th\\\/en\\\/#organization\",\"name\":\"MTECHNOLOGY\",\"url\":\"https:\\\/\\\/mtechnology.co.th\\\/en\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"th\",\"@id\":\"https:\\\/\\\/mtechnology.co.th\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/mtechnology.co.th\\\/en\\\/wp-content\\\/uploads\\\/2023\\\/05\\\/cropped-LOGO-METRO-COL-copy.png\",\"contentUrl\":\"https:\\\/\\\/mtechnology.co.th\\\/en\\\/wp-content\\\/uploads\\\/2023\\\/05\\\/cropped-LOGO-METRO-COL-copy.png\",\"width\":512,\"height\":512,\"caption\":\"MTECHNOLOGY\"},\"image\":{\"@id\":\"https:\\\/\\\/mtechnology.co.th\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/mtechnology.co.th\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/mtechnology.co.th\\\/en\\\/#\\\/schema\\\/person\\\/2bd4e3f6a4d5782ba602167ce70dbd29\",\"name\":\"jjsita26\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"th\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/ba831d0230b17e50bd4fdd186427b5174a55459be57fd540bd40ee842d3607a0?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/ba831d0230b17e50bd4fdd186427b5174a55459be57fd540bd40ee842d3607a0?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/ba831d0230b17e50bd4fdd186427b5174a55459be57fd540bd40ee842d3607a0?s=96&d=mm&r=g\",\"caption\":\"jjsita26\"},\"url\":\"https:\\\/\\\/mtechnology.co.th\\\/en\\\/author\\\/jjsita26\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"PoE (Power over Ethernet) Testing with the Fluke LinkIQ 100 - MTECHNOLOGY","description":"PoE (Power over Ethernet) is a technology that allows electrical power to be delivered over the same Ethernet cable as data","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/mtechnology.co.th\/en\/lan-system\/what-is-poe\/","og_locale":"th_TH","og_type":"article","og_title":"PoE (Power over Ethernet) Testing with the Fluke LinkIQ 100 - MTECHNOLOGY","og_description":"PoE (Power over Ethernet) is a technology that allows electrical power to be delivered over the same Ethernet cable as data","og_url":"https:\/\/mtechnology.co.th\/en\/lan-system\/what-is-poe\/","og_site_name":"MTECHNOLOGY","article_publisher":"https:\/\/www.facebook.com\/mtechnology.co.th","article_published_time":"2025-06-08T10:17:59+00:00","article_modified_time":"2025-06-16T10:26:26+00:00","og_image":[{"width":1200,"height":600,"url":"https:\/\/mtechnology.co.th\/en\/wp-content\/uploads\/2025\/06\/Fluke-LinkIQ-100-EN.jpg","type":"image\/jpeg"}],"author":"jjsita26","twitter_card":"summary_large_image","twitter_misc":{"Written by":"jjsita26","Est. reading time":"8 \u0e19\u0e32\u0e17\u0e35"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/mtechnology.co.th\/en\/lan-system\/what-is-poe\/#article","isPartOf":{"@id":"https:\/\/mtechnology.co.th\/en\/lan-system\/what-is-poe\/"},"author":{"name":"jjsita26","@id":"https:\/\/mtechnology.co.th\/en\/#\/schema\/person\/2bd4e3f6a4d5782ba602167ce70dbd29"},"headline":"PoE (Power over Ethernet) Testing with the Fluke LinkIQ 100","datePublished":"2025-06-08T10:17:59+00:00","dateModified":"2025-06-16T10:26:26+00:00","mainEntityOfPage":{"@id":"https:\/\/mtechnology.co.th\/en\/lan-system\/what-is-poe\/"},"wordCount":1194,"commentCount":0,"publisher":{"@id":"https:\/\/mtechnology.co.th\/en\/#organization"},"image":{"@id":"https:\/\/mtechnology.co.th\/en\/lan-system\/what-is-poe\/#primaryimage"},"thumbnailUrl":"https:\/\/mtechnology.co.th\/en\/wp-content\/uploads\/2025\/06\/Fluke-LinkIQ-100-EN.jpg","articleSection":["LAN System"],"inLanguage":"th","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/mtechnology.co.th\/en\/lan-system\/what-is-poe\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/mtechnology.co.th\/en\/lan-system\/what-is-poe\/","url":"https:\/\/mtechnology.co.th\/en\/lan-system\/what-is-poe\/","name":"PoE (Power over Ethernet) Testing with the Fluke LinkIQ 100 - MTECHNOLOGY","isPartOf":{"@id":"https:\/\/mtechnology.co.th\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/mtechnology.co.th\/en\/lan-system\/what-is-poe\/#primaryimage"},"image":{"@id":"https:\/\/mtechnology.co.th\/en\/lan-system\/what-is-poe\/#primaryimage"},"thumbnailUrl":"https:\/\/mtechnology.co.th\/en\/wp-content\/uploads\/2025\/06\/Fluke-LinkIQ-100-EN.jpg","datePublished":"2025-06-08T10:17:59+00:00","dateModified":"2025-06-16T10:26:26+00:00","description":"PoE (Power over Ethernet) is a technology that allows electrical power to be delivered over the same Ethernet cable as data","breadcrumb":{"@id":"https:\/\/mtechnology.co.th\/en\/lan-system\/what-is-poe\/#breadcrumb"},"inLanguage":"th","potentialAction":[{"@type":"ReadAction","target":["https:\/\/mtechnology.co.th\/en\/lan-system\/what-is-poe\/"]}]},{"@type":"ImageObject","inLanguage":"th","@id":"https:\/\/mtechnology.co.th\/en\/lan-system\/what-is-poe\/#primaryimage","url":"https:\/\/mtechnology.co.th\/en\/wp-content\/uploads\/2025\/06\/Fluke-LinkIQ-100-EN.jpg","contentUrl":"https:\/\/mtechnology.co.th\/en\/wp-content\/uploads\/2025\/06\/Fluke-LinkIQ-100-EN.jpg","width":1200,"height":600,"caption":"Fluke LinkIQ 100"},{"@type":"BreadcrumbList","@id":"https:\/\/mtechnology.co.th\/en\/lan-system\/what-is-poe\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/mtechnology.co.th\/en\/"},{"@type":"ListItem","position":2,"name":"PoE (Power over Ethernet) Testing with the Fluke LinkIQ 100"}]},{"@type":"WebSite","@id":"https:\/\/mtechnology.co.th\/en\/#website","url":"https:\/\/mtechnology.co.th\/en\/","name":"MTECHNOLOGY","description":"\u0e40\u0e21\u0e42\u0e17\u0e23 \u0e40\u0e17\u0e04\u0e42\u0e19\u0e42\u0e25\u0e22\u0e35","publisher":{"@id":"https:\/\/mtechnology.co.th\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/mtechnology.co.th\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"th"},{"@type":"Organization","@id":"https:\/\/mtechnology.co.th\/en\/#organization","name":"MTECHNOLOGY","url":"https:\/\/mtechnology.co.th\/en\/","logo":{"@type":"ImageObject","inLanguage":"th","@id":"https:\/\/mtechnology.co.th\/en\/#\/schema\/logo\/image\/","url":"https:\/\/mtechnology.co.th\/en\/wp-content\/uploads\/2023\/05\/cropped-LOGO-METRO-COL-copy.png","contentUrl":"https:\/\/mtechnology.co.th\/en\/wp-content\/uploads\/2023\/05\/cropped-LOGO-METRO-COL-copy.png","width":512,"height":512,"caption":"MTECHNOLOGY"},"image":{"@id":"https:\/\/mtechnology.co.th\/en\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/mtechnology.co.th"]},{"@type":"Person","@id":"https:\/\/mtechnology.co.th\/en\/#\/schema\/person\/2bd4e3f6a4d5782ba602167ce70dbd29","name":"jjsita26","image":{"@type":"ImageObject","inLanguage":"th","@id":"https:\/\/secure.gravatar.com\/avatar\/ba831d0230b17e50bd4fdd186427b5174a55459be57fd540bd40ee842d3607a0?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/ba831d0230b17e50bd4fdd186427b5174a55459be57fd540bd40ee842d3607a0?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/ba831d0230b17e50bd4fdd186427b5174a55459be57fd540bd40ee842d3607a0?s=96&d=mm&r=g","caption":"jjsita26"},"url":"https:\/\/mtechnology.co.th\/en\/author\/jjsita26\/"}]}},"_links":{"self":[{"href":"https:\/\/mtechnology.co.th\/en\/wp-json\/wp\/v2\/posts\/4292","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/mtechnology.co.th\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/mtechnology.co.th\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/mtechnology.co.th\/en\/wp-json\/wp\/v2\/users\/5"}],"replies":[{"embeddable":true,"href":"https:\/\/mtechnology.co.th\/en\/wp-json\/wp\/v2\/comments?post=4292"}],"version-history":[{"count":2,"href":"https:\/\/mtechnology.co.th\/en\/wp-json\/wp\/v2\/posts\/4292\/revisions"}],"predecessor-version":[{"id":4300,"href":"https:\/\/mtechnology.co.th\/en\/wp-json\/wp\/v2\/posts\/4292\/revisions\/4300"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/mtechnology.co.th\/en\/wp-json\/wp\/v2\/media\/4293"}],"wp:attachment":[{"href":"https:\/\/mtechnology.co.th\/en\/wp-json\/wp\/v2\/media?parent=4292"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/mtechnology.co.th\/en\/wp-json\/wp\/v2\/categories?post=4292"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/mtechnology.co.th\/en\/wp-json\/wp\/v2\/tags?post=4292"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}